TM 9-2350-256-10Table 2-1. PMCS-Continued.LocationCrewmemberNot FullyItemItem toMissionNo. IntervalCheck/ProcedureCapable if:Service53WeeklyM24/Tighten screws afterCont.M24A1 IRadjustment. BendPeriscopeheadrest to fit head. AllowNight5-minute warmup forCheckperiscope beforeadjusting focus.Remove dust caps fromleft and right focuscontrols. Loosen lock-nuts on focus controls.Using a screwdriver, turnView is not clearfocus controls andor is obstructed.ensure view through eye-piece is sharp and clear.Tighten locknuts. Putdust caps on left and rightfocus controls.Set IR POWER switch toM24 IR periscopeOFF. Set MASTERinoperative orBATTERY switch to OFF.missing.Set B.O. SELECTORswitch to B.O. DRIVE. SetLIGHTING CONTROLlevel to center (up)position.WARNINGWait at least 2 minutesafter IR POWER switchis turned off beforedisconnecting powercable. (High voltage ispresent at power cablefor several minutesafter IR POWER switchis OFF).2-90