TM 9-2350-256-10Table 2-1. PMCS-Continued.LocationCrewmemberNot FullyItemItem toMissionNo. IntervalCheck/ProcedureCapable if:Service54WeeklyANNVS-Set NIGHT VIEWER toCont.2(V)1AOFF. Disconnect powerPeriscopecable from receptacle.Connect power cable todummy receptacle.Install cap on receptacle.Install snap-on eyepiececover to periscope. Presslever and removeperiscope from mount.Remove battery cap andensure battery has beenremoved. Reinstallbattery cap.Install snap-on lens cover.Turn MASTER switch toOFF.55WeeklyPersonnela.Check for properHeateroperation.b.Inspect for fuel andb.Any fuel orexhaust leaks. exhaust leaks.56MonthlyHoist WinchUnwind cable and inspectAny cable withand Mainfor kinks, breaks, frayedkinks, breaks,Winchcondition, and properfrayed condition,Assemblywind on drum.or is missing.57MonthlyGPFUa.Turn switch to ON,check motor forsmooth operation andcheck outlets for airflow (refer to unitmaintenance).2-94