TM 9-2350-256-10(4)Operate purge pump (8) until back pressure is felt. Three or four strokes should do it. This will help get airout of lines. Do not press preheat button.CAUTIONDo not hold START button (9) in for longer than 15 seconds. If engine cranks butfails to start, turn off MASTER switch and wait 3 to 5 minutes. Repeat startingprocedures. If it does not start after third try, troubleshoot (see tab. 3-1).(5)Depress accelerator pedal (10) to its fullest travel. Push and hold START button until engine runs.Release button and pedal.CAUTIONIf master warning light does not go out in 20 seconds after engine starts, stopengine and notify unit maintenance.NOTEIf battery charge is too low to start engine, start APU (see para. 2-13e) and chargebatteries for 20 minutes or slave start vehicle (see para. 2-10d).(6)Adjust hand throttle (11) for 1000 to 1200 rpm and let engine warm up for 3 minutes. After 3 minutes returnengine to low idle (675 to 725 rpm) or depress accelerator pedal keeping engine speed at 1000 to 1200 rpmuntil engine runs smoothly.2-103