TM 9-2350-256-10
2-13. OPERATION OF AUXILIARY EQUIPMENT-Continued.
2.
Ensure FUEL PUMP CONTROL handle (7) is set to CLOSED.
3.
Move FLOW REGULATOR handle (8) to 10.
4.
Select filler tube for desired operation, long filler tube (9) to take fuel on (refuel), or short filler tube
(10) for defueling M88A1.
5.
Remove dust cap (11) from nozzle (12).
6.
Place filter (13) in filler tube (9 or 10). Remove dust cap (14) and screw tube onto nozzle (12)
hand tight. (If leakage occurs tube may be tightened slightly by wrench.) 7. Remove
compartment to outlet fuel hose connection cap (14) and fuel hose plug (15) and connect fuel
hose (16).
8.
Start APU (see para. 2-13e) and shift SYSTEM SELECTOR CONTROL lever (17) to REFUEL.
2-178