TM 9-2350-256-10(e)Transferpumpshutdown.1.Move FLOW REGULATOR handle (8) to 10.2.Set FUEL PUMP CONTROL handle (7) to CLOSED.3.Remove screw (19) and disconnect grounding cable (18). Reinstall screw.4.Engage nozzle (12) handle to relieve fuel pressure in hose. Remove tube (9 or 10) from fuel tankfiller pipe (22) and replace filler cap (21) and close fuel filler cover (20).5.Shift SYSTEM SELECTOR CONTROL lever (17) to MAIN.2-181