TM 9-2350-256-102-13. OPERATION OF AUXILIARY EQUIPMENT-Continued.9.Move FUEL PUMP CONTROL handle (7) to desired position (REFUEL places fuel into M88A1,DEFUEL removes fuel from the M88A1).10.Set FLOW REGULATOR control handle (8) to desired position. Refer to table 2-3 for flowsettings. Normal operating range will be 3.25 on flow regulator setting (26.5 gpm [100 Lpm]).CAUTIONAll personnel must dismount vehicles and manned fire extinguisher must bereadily accessible.11.Ground fuel hose assembly by connecting attached grounding cable (18) to object to/from whichfuel is being transferred with existing screw (19).12.Open fuel fill cover (20) and remove fuel filler cap (21) and insert filler tube (9 or 10) into tank fillerpipe (22). Avoid damaging filler pipes or strainers.CAUTIONWhen refueling M88A1, remove fuel filler cap (21) for venting and have an observerwatch fuel tank filler pipe (9 or 10) to avoid overfilling and spillage of fuel 13.Avoid overfilling by attending nozzle constantly.2-180