TM 9-2350-256-10NOTEUnit maintenance must replace used fire extinguishers.j.Fixed Fire Extinguisher System Operation.(1)General.The system contains two banks of four cylinders each. Pull handles are located on the left wall ofthe crew compartment behind the driver and forward of the left crew compartment door on the outside ofthe vehicle. These handles are used to discharge the fire extinguishers.NOTESome older vehicles have pull handles mounted above battery grille doors.(2)The fixed fire extinguishers will put out electrical and fuel fires in the hydraulic and engine compartments.(3)Operation.(a)To arm fixed fire extinguishersystem.Pull locking pin (1) andpush lever (2) forward on rearcylinder of each bank.2-187
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business