TM 9-2350-256-20-1
0047 00
CORRECTIVE ACTION Continued
6.
Reconnect switch panel to neutral safety to bulkhead wiring harness to main switch panel. Disconnect
wire 76 from FUEL PUMP switch side of 15 A circuit breaker. Place red lead of multimeter on terminal
of 15 A circuit breaker and black lead to ground. Turn MASTER switch on, and check for voltage.
Turn MASTER switch OFF. If voltage, is present, go to step 8. If voltage is not present, go to step 7.
7.
Reconnect wire 76 to FUEL PUMP switch side of 15 A circuit breaker. Disconnect wire 10 from 15
A circuit breaker. Place red lead of multimeter in wire 10 and black lead to ground. Turn MASTER
switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, replace circuit
breaker (see WP 0159 00). If voltage is not present, repair/replace wire 10 of main lighting and B.O.
selector switch wiring harness (see WP 0218 00).
0047 00-5