TM 9-2350-256-20-1
0067 00
CORRECTIVE ACTION Continued
4.
Reconnect switch panel to gage panel and miscellaneous switches wiring harness to main switch
panel. Disconnect wire 25/27 from 15 A circuit breaker. Place red lead of multimeter on terminal of
15 A circuit breaker and black lead to ground. Turn MASTER switch on and check for voltage. Turn
MASTER switch OFF. If voltage repair/replace wire 25/27 of main lighting and B.O. selector switch
wiring harness (see WP 0218 00). If voltage is not present, go to step 5.
5.
Reconnect wire 25/27 to 15 A circuit breaker. Disconnect wire 10 from 15 A circuit breaker. Place
red lead of multimeter in wire 10 and black lead to ground. Turn MASTER switch on and check for
voltage. Turn MASTER switch OFF. If voltage is present, replace circuit breaker (see WP 0159 00). If
voltage is not present, repair/replace wire 10 of main lighting and B.O. selector switch wiring harness
(see WP 0218 00).
0067 00-4