TM 9-2350-256-20-1
0068 00
Troubleshooting Procedure
Bilge Pump System and Electrical Accessories Panel Power Outlet
Symptom
Bilge pump system or electrical accessories panel power outlet malfunctioning.
Malfunction
Bilge pump fails to operate.
Do steps 1 thru 16.
Bilge pump indicator lamp fails to light and bilge pump operates. Do steps 1 and 2.
Electrical accessories panel power outlet has no power and bilge pump operates. Do step 17.
CORRECTIVE ACTION
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts a metal surface a direct
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
1.
Remove BILGE PUMP indicator lamp. Place red lead of multimeter in socket and black lead to ground.
Turn MASTER and BILGE PUMP switches ON and check for voltage. Turn MASTER and BILGE
PUMP switches OFF. If voltage is present, replace lamp (see WP 0158 00). If voltage is not present, go
to step 2.
0068 00-3