TM 9-2350-256-20-1
0068 00
CORRECTIVE ACTION Continued
6.
Disconnect wire 37/450 from panel connector side of circuit breaker. Place red lead of multimeter in
wire 37/450 and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER
switch OFF. If voltage is present, go to step 7. If voltage is not present, repair/replace wire 37/450 of
bilge pump main power wiring harness from circuit breaker to connector (see WP 0233 00).
7.
Reconnect wire 37/450 to panel connector side of circuit breaker. Disconnect wire 450 from BILGE
PUMP switch side of circuit breaker. Place red lead of multimeter on circuit breaker terminal and
black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If
voltage is present, go to step 8. If voltage is not present, replace circuit breaker (see WP 0158 00).
0068 00-6