TM 9-2350-256-20-1
0068 00
CORRECTIVE ACTION Continued
10. Reconnect electrical accessories panel wiring harness to electrical accessories panel. Install electrical
accessories panel (3), three lockwashers (2), and three screws (1). Open stowage basket forward
intermediate left floor plate. Disconnect bilge pump circuit breaker to switch panel lead assembly from
bilge pump relay. Place red lead of multimeter in socket A of wire 450B and black lead to ground. Turn
MASTER and BILGE PUMP switches ON and check for voltage. Turn MASTER and BILGE PUMP
switches OFF. If voltage is present, go to step 12. If voltage is not present, go to step 11.
11. Reconnect bilge pump circuit breaker to switch panel lead assembly. Disconnect wire 450B of electri-
cal accessories panel wiring harness from wire 450B of bilge pump lead relay wiring harness. Place
red lead of multimeter in female connector of wire 450B and black lead to ground. Turn MASTER
and BILGE PUMP switches switch ON, and check for voltage. Turn MASTER and BILGE PUMP
switches OFF. If voltage is not present, repair/replace wire 450B of electrical accessories panel wiring
harness (see WP 0196 00). If voltage is present, repair/replace 450B of bilge pump lead relay wiring
harness (see WP 0235 00).
0068 00-8