TM 9-2350-256-20-1
0068 00
CORRECTIVE ACTION Continued
8.
Reconnect wire 450 to BILGE PUMP switch side of circuit breaker. Disconnect wire 450 from circuit
breaker side of BILGE PUMP switch. Place red lead of multimeter in wire 450 and black lead to
ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is
present, go to step 9. If voltage is not present, repair/replace wire 450 from circuit breaker to bilge
pump switch (see WP 0233 00).
9.
Reconnect wire 450 to circuit breaker side of BILGE PUMP switch. Disconnect wire 450B from
panel connector side of BILGE PUMP switch. Place red lead of multimeter on BILGE PUMP switch
terminal and black lead to ground. Turn MASTER and BILGE PUMP switches ON and check for
voltage. Turn MASTER and BILGE PUMP switches OFF. If voltage is present, repair/replace wire
450B of bilge pump main power harness (see WP 0233 00). If voltage is not present, replace BILGE
PUMP switch (see WP 0158 00).
0068 00-7