TM 9-2350-256-20-1
0068 00
CORRECTIVE ACTION Continued
2.
Remove four screws (1) and four lockwashers (2) and release electrical accessories panel (3). Discon-
nect wire 450B from BILGE PUMP indicator light. Place red lead of multimeter on wire 450B and
black lead to ground. Turn MASTER and BILGE PUMP switches ON and check for voltage. Turn
MASTER and BILGE PUMP switches OFF. If voltage is present, replace lamp socket (see WP 0158
00). If voltage is not present, go to step 3.
3.
Disconnect electrical accessories panel wiring harness from electrical accessories panel. Place red lead
of multimeter in socket H of wire 450 and black lead to ground. Turn MASTER switch on and check
for voltage. Turn MASTER switch OFF. If voltage is present, go to step 5. If voltage is not present, go
to step 4.
0068 00-4