TM 9-2350-256-20-1
0071 00
CORRECTIVE ACTION Continued
2.
Remove eight screws (1) and door assembly (2). Remove lamp from socket assembly. Turn MASTER
switch on. Place red lead of multimeter on contact in center of socket and black lead to ground. Check
for voltage. Turn MASTER switch OFF. If voltage is not present, replace dome light assembly (see
WP 0183 00). If voltage is present, replace lamp (see WP 0183 00).
3.
Remove three screws (3), three lockwashers (4), ground lead (5), and flat washer (6) and release main
switch panel (7) from mounting brackets. Disconnect switch panel to gage panel and miscellaneous
switches wiring harness from main switch panel. Place red lead of multimeter on pin E of wire 10 and
black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If
voltage is present, go to step 6. If voltage is not present, reinstall main switch panel and go to step 9.
0071 00-4