TM 9-2350-256-20-1
0071 00
CORRECTIVE ACTION Continued
6.
Reconnect wire 38/999 to 15 A circuit breaker. Disconnect wire 10 from 15 A circuit breaker. Place
red lead of multimeter in wire 10 and black lead to ground. Turn MASTER switch on and check for
voltage. Turn MASTER switch OFF. If voltage is present, replace 15 A circuit breaker (see WP 0159
00). If voltage is not present, repair/replace wire 10 of main lighting and B.O. selector switch wiring
harness (see WP 0218 00).
7.
Disconnect electrical accessories panel wiring harness from electrical accessories panel. Place a
jumper wire from pin A to socket A of wire 38/59. Place red lead of multimeter on pin F of wire 38 and
black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If
voltage is present, repair/replace wire 38 of electrical accessories panel wiring harness (see WP 0196
00). If voltage is not present, go to step 8.
0071 00-6