TM 9-2350-256-20-1
0073 00
CORRECTIVE ACTION Continued
6.
Disconnect wire 999 from infrared power supply side of B.O. RECEIVER switch. Place red lead
of multimeter on switch terminal and black lead to ground. Turn MASTER and B.O. RECEIVER
switches on and check for voltage. Turn MASTER and B.O. RECEIVER switches OFF. If voltage is
present, repair/replace infrared power supply to B.O. RECEIVER switch wire 999 of switch panel to
gage panel and miscellaneous switches wiring harness (see WP 0205 00). If voltage is not present, go
to step 7.
7.
Reconnect wire 999 to B.O. RECEIVER switch. Disconnect wire 516 from main switch panel side
of B.O. RECEIVER switch. Place red lead of multimeter in wire 516 and black lead to ground. Turn
MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, replace
B.O. RECEIVER switch (see WP 0164 00). If voltage is not present, troubleshoot dome light circuit.
END OF WORK PACKAGE
0073 00-5/6 blank