TM 9-2350-256-20-1
0076 00
CORRECTIVE ACTION Continued
3.
Place red lead of multimeter in socket A of wire 38/59 and black lead to ground. Turn MASTER switch
on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 4. If voltage is
not present, go to step 8.
4.
Reconnect electrical accessories panel wiring harness to electrical accessories panel. Remove four
screws (1) and four lockwashers (2) and release electrical accessories panel (3) from mounting
brackets. Disconnect wire 38/518 from panel connector side of 15 A circuit breaker. Place red lead of
multimeter in wire 38/518 and black lead to ground. Turn MASTER switch on and check for voltage.
Turn MASTER switch OFF. If voltage is present, go to step 5. If voltage is not present, repair/replace
wire 38/518 of bilge pump main power wiring harness from panel connector to circuit breaker (see WP
0233 00).
0076 00-4