TM 9-2350-256-20-1
0077 00
CORRECTIVE ACTION Continued
switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 6. If
voltage is not present, go to step 7.
5.
Reconnect switch panel to gage panel and miscellaneous switches wiring harness to main switch panel.
Install main switch panel (11), flat washer (10), ground lead (9), three lockwashers (8), and three
screws (7). Disconnect wire 40 of gage panel to bulkhead wiring harness from switch panel to gage
panel and miscellaneous switches wiring harness. Place red lead of multimeter on male connector of
wire 40 and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER
switch OFF. If voltage is present, repair/replace wire 40 of gage panel to bulkhead wiring harness (see
WP 0194 00 for dual voltage; 0195 00 for single voltage). If voltage is not present, repair/replace wire
40 of switch panel to gage panel and miscellaneous switches wiring harness (see WP 0204 00 for dual
voltage; 0205 00 for single voltage).
0077 00-5