TM 9-2350-256-20-1
0077 00
CORRECTIVE ACTION Continued
6.
Place red lead of multimeter on pin N of wire 10/15 and black lead to ground. Turn MASTER switch
on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 7. If voltage is
not present, go to step 11.
7.
Reconnect switch panel to gage panel and miscellaneous switches wiring harness to main switch panel.
Disconnect main lighting and master relay wiring harness from main lighting switch. Place a jumper
wire from pin F to socket F. Place red multimeter lead on pin B of wire 40 and black lead to ground.
Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, go
to step 8. If voltage is not present, go to step 9.
0077 00-6