TM 9-2350-256-20-1
0088 00
CORRECTIVE ACTION Continued
3.
Reconnect wire to M2A2 air purifier. Disconnect wire from purifier side of purifier switch. Place
red lead of multimeter on switch terminal and black lead to ground. Turn MASTER and purifier
switches on and check for voltage. Turn MASTER and purifier switches OFF. If voltage is present,
repair/replace wire (see WP 0439 00). If voltage is not present, go to step 4.
4.
Reconnect wire to purifier switch. Disconnect wire from circuit breaker side of purifier switch. Place
red lead of multimeter in wire and black lead to ground. Turn MASTER switch on and check for
voltage. Turn MASTER switch OFF. If voltage is present, replace purifier switch (see WP 0441 00). If
voltage is not present, go to step 5.
0088 00-3