TM 9-2350-256-20-1
0086 00
CORRECTIVE ACTION Continued
7.
Reconnect electrical accessories panel wiring harness to electrical accessories panel. Disconnect wire
59 from ventilation blower. Place red lead of multimeter in wire 59 and black lead to ground. Turn
MASTER and VENT BLOWER switches ON and check for voltage. Turn MASTER and VENT
BLOWER switches OFF. If voltage is present, repair/replace ventilation blower (see WP 0250 00). If
voltage is not present, repair/replace wire 59 of electrical accessories panel wiring harness (see WP
0196 00).
8.
Reconnect electrical accessories panel wiring harness to electrical accessories panel. Open air inlet
doors (TM 9-2350-256-10). Disconnect wire 48 pin A from bulkhead to master relay wiring harness.
Place red multimeter lead in socket and black lead to ground. Turn MASTER switch on and check for
voltage. Turn MASTER switch OFF. If voltage is present, repair/replace switch panel, radio, and bilge
pump to bulkhead wiring harness (see WP 0202 00). If voltage is not present, troubleshoot master relay
END OF WORK PACKAGE