TM 9-2350-256-20-1
0086 00
CORRECTIVE ACTION Continued
5.
Reconnect wire 59 to blower switch side of 15 A circuit breaker. Disconnect wire 59 from circuit
breaker side of blower switch. Place red lead of multimeter in wire 59 and black lead to ground. Turn
MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step
F. If voltage is not present, repair/replace wire 59 of ventilation blower switch lead assembly (see WP
0158 00).
6.
Reconnect wire 59 to 15 A circuit breaker side of blower switch. Disconnect wire 59 from panel
connector side of blower switch. Place red lead of multimeter on terminal of blower switch and black
lead to ground. Turn MASTER and VENT BLOWER switches ON and check for voltage. Turn
MASTER and VENT BLOWER switches OFF. If voltage is present, repair/replace wire 59 of bilge
pump main power wiring harness (see WP 0233 00). If voltage is not present, replace ventilator blower
switch (see WP 0158 00).
0086 00-5