TM 9-2350-256-20-1
0086 00
CORRECTIVE ACTION
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts a metal surface a direct
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
1.
Disconnect electrical accessories panel wiring harness from electrical accessories panel. Place red lead
of multimeter in socket A of wire 38/59 and black lead to ground. Turn MASTER switch on and check
for voltage. Turn MASTER switch OFF. If voltage is present, go to step 2. If voltage is not present, go
to step 8.
2.
Place a jumper wire from socket A to pin A. Place red lead of multimeter on pin B of wire 59 and
black lead to ground. Turn MASTER and VENT BLOWER switches ON and check for voltage. Turn
MASTER and VENT BLOWER switches OFF. If voltage is present, go to step 7. If voltage is not
present, go to step 3.
0086 00-3