CORRECTIVE ACTION Continued
17. Reconnect wire 325 of red flasher breaker to switch cable to circuit breaker side FLASHER switch.
Disconnect wire 325 from FLASHER switch side of 15 A circuit breaker. Place red lead of multimeter
on circuit breaker terminal and black lead to ground. Turn MASTER switch on and check for voltage.
Turn MASTER switch OFF. If voltage is present, repair/replace wire 325 of red flasher breaker to
switch wiring harness from 15 A circuit breaker to FLASHER switch (see WP 0215 00). If voltage is
not present, go to step 18.
18. Reconnect wire 325 of red flasher breaker to switch wiring harness to switch side of 15 A circuit
breaker. Disconnect wire 325 of switch panel, radio and bilge pump to bulkhead wiring harness from
main switch panel side of 15 A circuit breaker. Place red lead of multimeter in wire 325 and black lead
to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is
present, replace 15 A circuit breaker (see WP 0160 00). If voltage is not present, reconnect wire 325
of switch panel, radio, and bilge pump to bulkhead wiring harness to main switch panel side of 15 A
circuit breaker.
0085 00-12