TM 9-2350-256-20-1
0085 00
CORRECTIVE ACTION Continued
7.
Place red lead of multimeter on pin N of wire 10 and black lead to ground. Turn MASTER switch on
and check for voltage. Turn MASTER switch OFF. If voltage is present, go to step 8. If voltage is
not present, reconnect switch panel to gage panel and miscellaneous switches wiring harness to main
switch panel and go to step 19.
Reconnect switch panel to gage panel and miscellaneous switches wiring harness to main switch panel.
8.
Disconnect main lighting and master relay wiring harness from main lighting switch. Place red lead of
multimeter in socket F of wire 10/15 and black lead to ground. Turn MASTER switch on and check
for voltage. Turn MASTER switch OFF. If voltage is present, go to step 9. If voltage is not present,
repair/replace wire 10/15 of main lighting and B.O. selector switch wiring harness (see WP 0218 00).
0085 00-7