TM 9-2350-256-20-1
0085 00
CORRECTIVE ACTION Continued
2.
Install bulb (3), cover (2), and tighten four screws (1). Disconnect wire 17 from failed rigger's service
light. Place red lead of multimeter in wire 17 and black lead to ground. Turn MASTER switch
ON, press STOP LIGHT and ENTER key on main light switch and set rigger's B.O. SELECTOR
to SERVICE position, and check for voltage. Turn MASTER, main lighting, and rigger's B.O.
SELECTOR switches OFF. If voltage is present, replace rigger's service light assembly (see WP 0176
00). If voltage is not present, go to step 3.
3.
Reconnect wire 17 to light. Disconnect wire 17 from rigger's SERVICE switch. Place red lead of
multimeter on switch terminal and black lead to ground. Turn MASTER switch ON, press STOP
LLIGHT key and ENTER key on main light switch, set rigger's B.O. SELECTOR to SERVICE
position, and check for voltage. Turn MASTER, main lighting, and rigger's B.O. SELECTOR
switches OFF. If voltage is present, go to step 4. If voltage is not present, go to step 5.
0085 00-4