TM 9-2350-256-20-1
0086 00
CORRECTIVE ACTION Continued
3.
Remove four screws (1) and four lockwashers (2) and release electrical accessories panel (3) from
mounting brackets. Ground panel. Reconnect electrical accessories panel wiring harness to electrical
accessories panel. Disconnect wire 38/59 from 15 A circuit breaker. Place red lead of multimeter in
wire 38/59 and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER
switch OFF. If voltage is present, go to step 4. If voltage is not present, repair/replace wire 38/59 of
bilge pump main power wiring harness (see WP 0233 00).
4.
Reconnect wire 38/59 to 15 A circuit breaker. Disconnect wire 59 from blower switch side of 15 A
circuit breaker. Place red lead of multimeter on terminal of 15 A circuit breaker and black lead to
ground. Turn MASTER switch on and check for voltage. Turn MASTER switch OFF. If voltage is
present, go to step 5. If voltage is not present, replace 15 A circuit breaker (see WP 0158 00).
0086 00-4