2.
Reconnect wire 664A to hydraulic oil temperature gage. Disconnect wire 325 from hydraulic oil
temperature gage side of 15 A circuit breaker. Place red lead of multimeter on terminal of 15 A circuit
breaker and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER
switch OFF. If voltage is present, repair/replace wire 664A of red flasher breaker to switch wiring
harness (see WP 0215 00). If voltage is not present, go to step 3.
3.
Reconnect wire 325 to hydraulic oil temperature gage side of 15 A circuit breaker. Disconnect wire
325 of switch panel, radio, and bilge pump to bulkhead wiring harness from 15 A circuit breaker. Place
red lead of multimeter in wire 325 and black lead to ground. Turn MASTER switch on and check for
voltage. Turn MASTER switch OFF. If voltage is present, replace 15 A circuit breaker (see WP 0160
00). If voltage is not present, go to step 7.