TM 9-2350-256-20-1
0091 00
CORRECTIVE ACTION Continued
6.
Reconnect flasher system panel wiring harness to hydraulic reservoir disconnect. Disconnect wire 664
and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch
OFF. If voltage is present, replace hydraulic oil temperature transmitter (see WP 0425 00). If voltage is
not present, repair/replace wire 664 from hydraulic reservoir disconnect to hydraulic oil temperature
transmitter (see WP 0237 00).
7.
Reconnect wire 325 of switch panel, radio, and bilge pump to bulkhead wiring harness from 15 A circuit
breaker. Open air inlet doors (TM 9-2350-256-10). Disconnect wire 48 pin A from bulkhead to master
relay wiring harness. Place red multimeter lead in socket and black lead to ground. Turn MASTER
switch on and check for voltage. Turn MASTER switch OFF. If voltage is present, repair/replace
switch panel, radio, and bilge pump to bulkhead wiring harness (see WP 0202 00). If voltage is not
present, troubleshoot master relay circuit (see WP 0042 00).
END OF WORK PACKAGE
0091 00-6