TM 9-2350-256-20-1
0096 00
ITEM
INTERVAL
MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY
SERVICED
AVAILABLE IF:
d. Perform continuity checks on system as follows:
1)
Place MASTER switch in ON position.
2)
Place power (arming) switch in ON position.
3)
Depress and hold L hand push button.
4) Check to see if approximately 24 volts exists on
plug pins in tubes (5, 2, and 1) on left discharger and (3,
6, and 4) on right discharger. No voltage should exist on
any other plug pins.
5) Release L hand push button and depress and hold R
hand push button.
6) Check to see if approximately 24 volts exists on
plug pins in tubes (3, 6, and 4) on left discharger and (5,
2, and 1) on right discharger. No voltage should exist on
any other plug pins.
0096 00-11