TM 9-2350-256-20-1
0098 00
16. Remove personnel heater exhaust hose assembly (29) by removing four screws (30), four lockwashers (31), gasket (32),
two screws (33), two lockwashers (34), and gasket (35).
17. Remove APU housing (36) by removing three screws (37) and three lockwashers (38).
18. Loosen clamp (39) and disconnect generator air intake hose (40).
19. Disconnect throttle linkage (41) by removing screw (42) and nut (43) and pulling hand throttle at driver's control all the
way out.
21. Disconnect emergency fuel shutoff linkage (45) by removing flat washer (46) and cotter pin (47) from link (48).
22. Remove emergency fuel shutoff linkage bracket (49) by removing two screws (50) and two lockwashers (51).
0098 00-5