TM 9-2350-256-20-2
0154 00
Removal
1.
2.
Remove access cover (1) by removing four screws (2) and four lockwashers (3).
3.
Remove ground strap (4) by removing screw (5) from one end of ground strap and screw (6) and lockwasher (7) from other
end of ground strap.
4.
Disconnect two wiring harnesses (8) and two wiring harnesses (9) from mounting bracket (10) by removing four clamps
(11), four screws (12), four lockwashers (13), and four nuts (14).
5.
Remove screw (15) and ground wire (16).
6.
Remove two wiring harnesses (8) from APU voltage regulator (17) and two wiring harnesses (9) from main engine voltage
regulator (18).
7.
Remove mounting bracket (10) by removing two screws (19), four flat washers (20), and two nuts (21).
8.
Remove two mounting brackets (22) by removing four screws (23) and four lockwashers (24).
9.
Remove mounting plate (25) by removing eight screws (26) and eight lockwashers (27).
NOTE
Flat washers (28) are used in single voltage regulator configurations only.
0154 00-2