TM 9-2350-256-20-2
0159 00
Removal
1.
Remove two nuts (1), three screws (2), three lockwashers (3), end of ground lead (4), and flat washer (5) from main switch
panel (6).
NOTE
Identify connectors upon removal to ensure proper installation.
2.
Pull main switch panel (6) forward and disconnect three connectors (7).
Disassembly
1.
Remove ground strap (4) and retainer (8) by removing two screws (9), lockwasher (10), and two flat washers (11) from
main switch panel (6).