TM 9-2350-256-20-2
0194 00
Removal
NOTE
Gage panel shown removed for clarity.
1.
Remove 19 clamps (11) by removing screw (12) and lockwasher (13) from each.
2.
Remove connector (1) from gage panel bracket (14) by removing four screws (15) and four lockwashers (16).
3.
Disconnect connector (2) from APU control box to foot dimmer switch and bulkhead wiring harness (17).
4.
Disconnect connector (3) from powerpack warning horn relay (18).
5.
Disconnect connector (4) from powerpack warning horn assembly (19).
0194 00-3