0194 00
11. Disconnect two connectors (10 and 11) from switch panel to gage panel and miscellaneous switches wiring harness (28).
Disassembly
1.
Disassemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
Assembly
1.
Assemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
Installation
1.
Connect two connectors (10 and 11) to switch panel to gage panel and miscellaneous switches wiring harness (28).
2.
Connect connector (9) to power control switch (27).
3.
4.
Install ground lead (7) using bolt (25).
5.
Connect connector (6) to mechanical transmission low oil pressure switch (24).
6.
Install connector (5) and gasket (23) to bulkhead disconnect (20) using four screws (21) and four lockwashers (22).