TM 9-2350-256-20-2
0402 00
14. Install two adjustable elbow brackets (41) with two screws (42).
15. Install two adjustable elbows (40) on two cables (35) and two conduits (38) and secure with two screws (39).
16. Install two conduits (43) and two swivel connectors (44) on two cables (35).
NOTE
Remove slack from cables.
NOTE
Pull splice to inlet end of barrel before attaching to cylinder valve. Apply thin coat of graphite to cable
before installing.
17. Install four cables (4 and 35) in two dual-pull mechanisms (48) with two cable clamps (52). Insert cable into cable clamp.
Squeeze cable clamp tightly along its entire length using pliers, or flatten securely by tapping lightly with a hammer. Grasp
3/16 in. (5 mm) of each end of cable clamp with pliers. Rotate ends of cable clamp in opposite directions simultaneously
until cable clamp has been twisted 1-1/2 turns. Cut short end of cable to within 1/16 in. (2 mm) of cable clamp.
0402 00-8