TM 9-2350-256-20-2
0439 00
11. Place ground wire (6) between frame assembly (21) and M2A2 air purifier (3). Install M2A2 air purifier in frame assembly
by closing catch assembly (22).
12. Install two clamps (13) and clamp (15) each with screw (19) and lockwasher (20).
13. Connect mechanic's hose (14) between manifold of M2A2 air purifier (3) and clamp (15). Secure hose with six clamps
(16), each held by screw (17) and lockwasher (18).
14. Connect rigger's hose (11) and commander's hose (12) between manifold of M2A2 air purifier (3) and clamps (13).
15. Install circuit breaker and switch assembly (2) with two screws (9) and two lockwashers (10).
16. Connect ground wire (6) on M2A2 air purifier (3) with screw (7) and lockwasher (8).
17. Connect cable assembly (4) between circuit breaker and switch assembly (2) and dome light (5).
18. Connect cable assembly (1) between circuit breaker and switch assembly (2) and M2A2 air purifier (3).
0439 00-8