TM 9-2350-256-20-2
0440 00
Removal
1.
Disconnect cable assembly (1) from M2A2 air purifier (2).
2.
Remove ground wire (3) from M2A2 air purifier (2) by removing screw (4) and lockwasher (5).
3.
Tag and disconnect hoses (6).
4.
Remove M2A2 air purifier (2) from frame assembly (7) by opening catch assembly (8).
Disassembly
1.
Remove four airflow caps (9).
2.
Remove manifold assembly (10) by removing three screws (11) and three lockwashers (12).
3.
Remove filters (13 and 14) and spring clip (15) from housing (16).
Assembly
1.
Install spring clip (15) and filters (13 and 14) to housing (16).
2.
Install manifold assembly (10) with three screws (11) and three lockwashers (12).
3.
Install four airflow caps (9).
Installation
1.
Place ground wire (3) between frame assembly (7) and M2A2 air purifier (2). Install M2A2 air purifier in frame assembly
and close catch assembly (8).
2.
Install ground wire (3) to M2A2 air purifier (2) with lockwasher (5) and screw (4).
3.
Reconnect hoses (6) and remove tags.
4.
Connect cable assembly (1).
5.
Test M2A2 air purifier (see WP 0114 00).
END OF WORK PACKAGE
0440 00-2