CHAPTER 9: MAINTENANCE OF HULL- AND CAB-RELATED COMPONENTS
TM 9-2350-256-20
9-93 REPLACE OXYGEN TANK STRAP ASSEMBLIES - Continued
NOTE
Oxygen tank shown for clarity.
a. REMOVAL
1
Remove four straps (1 and 2) by removing four
cotter pins (3), four flat washers (4), and four
straight pins (5).
2
Remove nut (6) and lockwasher (7) from each bolt
(8).
3
Remove bolt (8) from each of two straps (2) by
removing cotter pin (9), flat washer (10), and
straight pin (11).
b. INSTALLATION
1
Install bolt (8) to each of two straps (2) with
straight pin (11), flat washer (10), and new cotter
pin (9).
2
Install new lockwasher (7) and nut (6) to each bolt
(8).
3
Install four straps (1 and 2) with four straight pins
(5), four flat washers (4), and four new cotter pins
(3).
NOTE
Follow-on maintenance: Install oxygen tank (refer to TM 9-23560-256-10)
9-94 REPLACE/REPAIR PIONEER TOOL SET BRACKET
THIS TASK COVERS
a. Removal
b. Disassembly
c. Assembly
d. Installation
INITIAL SET-UP
Tools:
Parts:
Equipment Condition:
Tool kit, general mechanic's
Lockwashers (4) (Appendix G,
Pioneer tool set removed (refer to
(Appendix C, item 53)
item 132)
TM 9-2350-256-10)
a. REMOVAL
1
Remove strap (1).
2
Remove pioneer tool set bracket (2) by removing four screws (3), four lockwashers (4), and two flat washers
(5).