SECTION III: PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)TM 9-2350-256-20LocationItem ToNot FullyItemCheck/MissionNo.IntervalServiceProcedureCapable If:WARNINGRemove all jewelry such as rings, dog tags,bracelets, etc. If jewelry contacts a metal surfacea direct short may result in instant heating oftools, damage to equipment, and injury ordeath to personnel.Sd. Perform continuity checks on system as follows:(1) Place MASTER switch in ON position.(2) Place power (arming) switch in ON position.(3) Depress and hold L hand push button.(4) Check to see if approximately 24 volts exists onplug pins in tubes (5, 2, and 1) on left discharger,and (3, 6, and 4) on right discharger. No voltageshould exist on any other plug pins.(5) Release L hand push button and depress and holdR hand push button.(6) Check to see if approximately 24 volts exists onplug pins in tubes (3, 6, and 4) on left dischargerand (5, 2, and 1) on right discharger. No voltageshould exist on any other plug pins.2-17