SECTION III: PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)TM 9-2350-056-20LocationItem ToNot FullyItemCheck/MissionNo.IntervalServiceProcedureCapable If:7STorsion BarVisually inspect torsion bar anchors to ensure that they areTwo or moreAnchorsfully seated and retaining screws are in place and secure.torsion barTorque screws to 40-50 lb-ft (54-68 N-m).anchorsunservice-able on anyone side8SDraina. Operate drain valve lever to assure free operation ofValves andtwo drain valves (located at front and rear of undersideDrain Valveof hull). The drain valves should seal openingsSealscompletely when closed.Sb. Inspect drain valve bearing surfaces for nicks, dents,scored bearing surface, and out-of-roundness.9SDecals,a. Replace decals and name plates that are not legible.NamePlates,NOTEStencils,MarkingsRefer to TM 9-213 for painting information andand Paintprocedures.Sb. Restencil markings that are not legible.2-13