REMOVAL
REPLACE/REPAIR BILGE PUMP CIRCUIT BREAKER TO SWITCH PANEL LEAD (10894546)
TM-9-2350-256-20 Carrier Cargo Tracked 6-Ton M548A1 (2350-01-096-9356) M548A3 2350-01-369-6081 Manual
Page Navigation
764
765
766
767
768
769
770
771
772
773
774
CHAPTER 6: MAINTENANCE OF ELECTRICAL SYSTEMS AND CIRCUITS
TM 9-2350-256-20
6-84 REPLACE/REPAIR BILGE PUMP MAIN POWER WIRING HARNESS
(1 0945008)--Continued ..
2 Disconnect connector (2) from vent blower switch (17).
3 Disconnect connector (3) from
circuit breaker
no. 1 (18).
4 Disconnect connector (4) from
circuit breaker
no. 2 (19).
5 Disconnect two connectors (5 and 6) from winch light switch (20).
6 Disconnect connector (7) from
circuit breaker
no. 2 (19).
7 Disconnect connector (8) from circuit breaker no. 3 (21).
8 Disconnect connector (9) from bilge pump indicator light (22).
9 Disconnect connector (10) from bilge pump switch (23).
10 Disconnect two connectors (11 and 12) from
generator
cutout switch (24).
b. DISASSEMBLY
Disassemble wiring harness (see Chapter 6, Section VII).
c. ASSEMBLY
Assemble wiring harness (see Chapter 6, Section VII).
d. INSTALLATION
1 Connect two connectors (11 and 12) to
generator
cutout switch (24).
2 Connect connector (10) to bilge pump switch (23).
6-228