6-86 REPLACE/REPAIR BILGE PUMP LEAD RELAY WIRING HARNESS AND CAP
(10894548)--Continued
6 Disconnect connector (4) from bilge pump (12).
NOTE
Bilge pump is part of deep water fording
kit. Perform step 6 if deep water fording
kit is installed.
b. DISASSEMBLY
Disassemble wiring harness (see Chapter 6, Section
VI).
c. ASSEMBLY
Assemble wiring harness (see Chapter 6, Section VII).
d. INSTALLATION
NOTE
Perform step 1 only if deep water fording
kit is installed.
1 Connect connector (4) to bilge pump (11).
2 Install strap (5).
3 Install cap assembly (10) on connector (4).
4 Connect lead (3) to circuit breaker (7) using screw (8) and new lockwasher (9).
5 Connect connector (2) to bilge pump relay (6).
6 Connect connector (1) to electrical accessories panel wiring harness (5).
NOTE
Follow-on maintenance: Close stowage basket forward intermediate left floor plate (see paragraph 9-21)