SECTION VI: MISCELLANEOUS ELECTRICAL COMPONENTSTM 9-2350-256-20WARNINGBe certain MASTER switch is OFF when working on electrical systems to avoid electrical shock orbums.a. REMOVAL1 Disconnect two leads (1 and 2) from circuit breaker (3) by removing two screws (4) and two lockwashers (5).2 Disconnect wiring harness (6) from relay (7).3 Remove circuit breaker (3) by removing two screws (8) and two lockwashers (9).4 Remove relay (7) by removing two screws (10) and two lockwashers (11).5 Remove plate (12) by removing two screws (13) and two lockwashers (14).b. INSTALLATION1 Install plate (12) using two new lockwashers (14) and two screws (13).2 Install relay (7) using two new lockwashers (11) and two screws (10).3 Install circuit breaker (3) using two new lockwashers (9) and two screws (8).4 Connect wiring harness (6) to relay (7).5 Connect two leads (1 and 2) to circuit breaker (3) using two new lockwashers (5) and two screws (4).NOTEFollow-on maintenance: Close stowage basket forward intermediate left floor plate (see paragraph 9-21)6-259