SECTION VI: MISCELLANEOUS ELECTRICAL COMPONENTS
TM 9-2350-256-20
WARNING
Be certain MASTER switch is OFF when working on electrical systems to avoid electrical shock orbums.
a. REMOVAL
1 Disconnect two leads (1 and 2) from circuit breaker (3) by removing two screws (4) and two lockwashers (5).
2 Disconnect wiring harness (6) from relay (7).
3 Remove circuit breaker (3) by removing two screws (8) and two lockwashers (9).
4 Remove relay (7) by removing two screws (10) and two lockwashers (11).
5 Remove plate (12) by removing two screws (13) and two lockwashers (14).
b. INSTALLATION
1 Install plate (12) using two new lockwashers (14) and two screws (13).
2 Install relay (7) using two new lockwashers (11) and two screws (10).
3 Install circuit breaker (3) using two new lockwashers (9) and two screws (8).
4 Connect wiring harness (6) to relay (7).
5 Connect two leads (1 and 2) to circuit breaker (3) using two new lockwashers (5) and two screws (4).
NOTE
Follow-on maintenance: Close stowage basket forward intermediate left floor plate (see paragraph 9-21)
6-259