TM 9-2350-256-34
0048 00
1.
Remove old linings (16) from retaining strap (8), mounting bracket (9), and fixed arm assembly (11).
2.
Use old linings (16) as patterns and cut new linings to the same sizes.
3.
Position linings (16) on retaining strap (8), mounting bracket (9), and fixed arm assembly (11).
4.
Set the rivet tangs below the lining surface so that the surface is smooth. Peen over properly to hold securely in place.
Assembly
NOTE
There are two portable fire extinguisher stowage boxes and brackets. This procedure covers one.
1.
Install nut (15), lockwasher (14), rod connector (13), nut (12), fixed arm assembly (11), and rivet (10) to mounting bracket
(9).
2.
Install retaining strap (8), lockwasher (7), nut (6), connecting link (5), rivet (4), rod end clevis (3), straight pin (2), and cotter
pin (1) to mounting bracket (9).
Installation
1.
Install portable fire extinguisher stowage boxes and brackets in accordance with TM 9-2350-256-20.
END OF WORK PACKAGE