TM 9-2350-256-34
0063 00
Removal
1.
Remove six knobs (1).
2.
Remove three clamps (2) and wiring harness (3).
3.
Disconnect two electrical connectors (4).
4.
Remove two cotter pins (5), pin (6), and disconnect linkage (7). Discard cotter pins.
5.
Remove two screws (8), lockwashers (9), and drain valve control (10). Discard lockwashers.
CAUTION
Close APU emergency winch control valve (18) for main hydraulic system operation.
6.
Disconnect two hydraulic lines (11).
NOTE
Perform steps 7 thru 9 to replace APU emergency winch control valve (18) only. If not replacing APU
emergency winch control valve, proceed to step 10.
7.
Remove four nuts (12), lockwashers (13), two U-clamps (14), and plate (15). Discard lockwashers.
8.
Remove capscrew (hidden) (16) and handle (17).
9.
Unscrew APU emergency winch control valve (18).
0063 00-2