TM 9--2350--292--20--1
ENGINE OIL SAMPLING VALVE REPLACEMENT
0195 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Tools and Special Tools
General mechanics tool kit (item 1, WP 0717 00)
Equipment Conditions
Engine oil drained (WP 0187 00)
Removal
1. Remove oil sampling valve (1) from cover (2).
2. Inspect parts for damage and replace as required.
Installation
CAUTION
Make sure oil sampling valve lever is parallel to oil filter
cover and that protective cap is installed and secured on
sampling valve. Failure to properly position oil sampling
valve lever and secure protective cap may result in loss
of engine oil and equipment damage.
Install oil sampling valve (1) in cover (2).
Figure 5
2
1
POWERPACK
REMOVED FOR CLARITY
NOTE
FOLLOW--ON MAINTENANCE:
Fill engine with oil (WP 0187 00)
END OF TASK
0195 00--1/2 blank