TM 9--2350--292--20--1
0242 00--14
MAIN SWITCH PANEL ASSEMBLY REPAIR -- CONTINUED
0242 00
Assembly--Continued
NOTE
There are seven circuit breakers in the main switch panel
assembly. There are two 20--amp and five 15--amp cir-
cuit breakers. All seven are installed in the same man-
ner. Perform step 14 to install one circuit breaker.
14. Install circuit breaker (42, 43, 44, 45, 46, 56, or 58) in main switch panel assembly (6) with two screws (65), two
new lockwashers (64) and two nuts (63).
Figure 51
6
6
NOTE:
TYPICAL CIRCUIT BREAKER
ARRANGEMENT SHOWN
42
46
58
65
64
63
43
56
45
44