TM 9--2350--292--20--1
0271 00--2
MASTER RELAY, MOUNTING BRACKET AND COVER REPLACEMENT --
CONTINUED
0271 00
Removal
1. Remove two nuts (1), two lockwashers (2), four flat washers (3) and master relay cover (4) from mounting bracket
(5). Discard lockwashers.
2. Remove screw (6), lockwasher (7), wiring harness 3W217 terminals T1 and T2 (8), wiring harness 3W702 wire 66
(9), lockwasher (10) and nut (11) from master relay terminal A2 (12). Discard lockwashers.
3. Remove screw (13), three lockwashers (14), two lead assemblies 3W215 terminals T2 (15), flat washer (16),
lockwasher (17) and nut (18) from master relay terminal A1 (19). Discard lockwashers.
4. Remove screw (20), spring tension washer (21), flat washer (22) and wiring harness 3W142 wire 459B (23) from
master relay terminal X1 (24). Discard spring tension washer.
5. Remove screw (25), spring tension washer (26), flat washer (27) and lead assembly 3W174 wire GND (28) from
master relay terminal X2 (29). Discard spring tension washer.